English
Language : 

TFS751 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 751.doc
Vectron International
Measurement condition
Ambient temperature:
23
Input power level:
0
Terminating impedance:
Input:
50
Output:
50
Version 1.3
Filter specification
°C
dBm
Ω
Ω
TFS 751
06.03.2009
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 751,5 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band ripple
Absolute attenuation
776
MHz ... 787
788
MHz ... 805
806
MHz ... 849
Return loss within PB
Input power level
p-p
MHz
MHz
MHz
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
ae
fN
PB
arel
OTR
TCf *
typ. value
1,7 dB
-
-
0,8 dB
35
dB
35
dB
33
dB
13
dB
-
-
-
-39
ppm/K
tolerance / limit
max.
3,0 dB
fN
±
max.
751,5
5,5
1,5
MHz
MHz
dB
min.
15 dB
min.
20 dB
min.
20 dB
min.
10 dB
max.
15 dBm
- 25 °C ... + 85 °C
- 40 °C ... + 85 °C
-
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.