English
Language : 

TFS737 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 737.doc
Vectron International
Version 3.0
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
50
Ω
50
Ω
TFS 737
27.11.2012
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 737,0 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Pass band variation
Absolute attenuation
0,3
697
714
757
762
866
967
1934
MHz ... 697
MHz ... 714
MHz ... 717
MHz ... 762
MHz ... 866
MHz ... 967
MHz ... 1934
MHz ... 3000
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Return loss within PB
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
ae
fN
PB
aabs
OTR
TCf **
typ. value
2,5 dB
-
-
0,83 dB
39
dB
32
dB
21
dB
15
dB
27
dB
39
dB
34
dB
11
dB
13
dB
-
-
-
-45
ppm/K
tolerance / limit
max.
3,5 dB
737,0
fN ±
max.
10,0
2,0
MHz
MHz
dB
min.
35 dB
min.
22 dB
min.
10 dB
min.
10 dB
min.
22 dB
min.
30 dB
min.
25 dB
min.
8 dB
min.
10 dB
max.
5 dBm
- 35 °C ... + 85 °C
- 50 °C ... +125 °C
-
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.