English
Language : 

TFS70Y Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter Specification
tfs70y.doc
VI TELEFILTER
Version 3.0
Filter Specification
TFS 70 Y
06.06.2003
1/5
1. Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances in fc * ) :
for input:
for output:
External coil:
23 °C.
0 dBm.
2,9 kOhm -3,8 pF
2,9 kOhm -3,8 pF
820 nH
2. Characteristics :
Remark: Reference level for the relative attenuation arel of the TFS70Y is the minimum of the pass band attenuation amin. The minimum of the
pass band attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the
reference frequency fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating
temperature range is not included in the production tolerance scheme.
Data
typ. value
Variation / Limitation
Insertion Loss
ae
(Reference Level)
3,7 dB
max 6,0 dB
Centre frequency
(at ambient temperature TA)
Relative Attenuation
fN - 35
fN ± 35
kHz ... fN + 35
kHz ... fN ± 47
fN ± 60
fN ± 90
fN ± 450
fN ± 500
kHz ... fN ± 90
kHz ... fN ± 450
kHz ... fN ± 500
kHz ... fN ± 10
fc
arel
kHz
kHz
kHz
kHz
kHz
MHz
70,002 MHz
0,5 dB
2 dB
2,5 dB
10 dB
45 dB
43 dB
70,0 ± 0,015 MHz
max. 1 dB
max. 3 dB
min. 1 dB
min. 3 dB
min. 35 dB
min. 40 dB
Temperature Coefficient
Turn over temperature
Tcf 2nd order **)
T0
Operating Temperature Range
Storage Temperature Range
- 0,043 ppm/K
25 °C
-
-
-
-
- 5 °C ... + 70 °C
- 30 °C ... + 90 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) fc(Hz) = Tcf(ppm/K) x (T - To)² x fTo (MHz)
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.