English
Language : 

TFS70H41 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 70h41.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
input:
output:
25
°C
0
dBm
410 Ω // -12,0 pF
610 Ω // - 9,6 pF
TFS 70H41
16.11.2004
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 70H41 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the
production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
Centre frequency
Passband
Bandwidth
1 dB
3 dB
40 dB
Relative attenuation
fC
fC ±
fC ±
9,4
10,3
… fC ±
MHz … fC ±
MHz … fC ±
ae
fC
PB
BW
arel
9,4 MHz
10,3 MHz
11
MHz
21,8 dB
-
21,09
22,84
27,78
MHz
MHz
MHz
0,6 dB
0,6 dB
2
dB
max.
23 dB
70,0 ± 0,20 MHz
fC ± 11 MHz
min.
min.
max.
max.
max.
max.
20,6 MHz
22,0 MHz
28,2 MHz
0,8 dB
1 dB
3 dB
fC ± 14,1 MHz … fC ± 27
fC ± 27
MHz … fC ± 60
Group delay ripple within PB
MHz
MHz
45
dB
60
dB
45
ns
min.
min
max.
40 dB
55 dB
60 ns
Phase ripple within PB
4,5 °
max.
6 ° p-p
Operating temperature range
OTR
-
- 25 °C ... + 80°C
Storage temperature range
-
- 40 °C ... + 85°C
Temperature coefficient of frequency
TCf **
-83
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.