English
Language : 

TFS70F1 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter Specification
tfs70f1.doc
VI TELEFILTER
Filter Specification
Version 2.4
09.04.2001
TFS 70 F1 1/5
1. Measurement condition :
Ambient temperature TA:
Input power level:
Terminating impedances at fc:
25 °C
0 dBm.
for input:
for output:
56 Ω  -30 pF.
56 Ω  -30 pF.
2. Characteristics :
Remark:
Reference level for the relative attenuation arel of the TFD 70F1 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at
the 3 dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency
fc and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is
not included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss (Reference level) ae
Reference frequency fc at ambient temperature (fCTA)
Pass band ( PB ) at ambient temperature TA:
Amplitude ripple in PB (p-p):
22,5 dB
70 MHz
0,5 dB
max. 25 dB
70 ± 0,10MHz
fC - 6,1 MHz .... fC + 6,1 MHz
max. 1,0dB
Bandwidth at ambient temperature :
1 dB - band width
3 dB - band width
40 dB - band width
45 dB - band width
50 dB - band width
12,24
12,45
13,23
13,30
13,32
MHz
MHz
MHz
MHz
MHz
min. 12,2 MHz
min. 12,4 MHz
max. 13,3 MHz
Relative attenuation
arel
fc ..... fc ± 6,1 MHz
fc ± 6,1 MHz fc ± 6,2 MHz
fc ± 6,65 MHz
fc ± 6,8 MHz
fc ± 7,2 MHz
fc ± 8 MHz
fc ± 10,2 MHz
fc ± 18,2 MHz
fc ± 6,8 MHz*)
fc ± 7,2 MHz*)
fc ± 8 MHz
fc ± 10,2 MHz
fc ± 18,2 MHz*)
fc ± 35 MHz
Group delay ( mean value in PB )
Group delay ripple (p-p):
fc ... fc ± 6 MHz
Deviation from linear phase (p-p): fc ... fc ± 6 MHz
Triple transit attenuation compared to main signal
Input/Output return loss with matching network (S11/S22):
Crosstalk
-
-
45 dB
48 dB
52 dB
55 dB
45 dB
45 dB
4,1
100
7,5°
µs
ns
(p-p)
52
dB
4 / 3,5 dB
65
dB
max. 1 dB
max. 3 dB
min. 40 dB
min. 45 dB
min. 48 dB
min. 50 dB
min. 40 dB
min. 40 dB
max. 4,5 µs
max. 200 ns
Substrate material
Temperature coefficient of frequency ( Tcf )
Frequency deviation of fc over temperature
Operating temperature range
Storage temperature range
LiNbO3
-86 ppm/K
-94 ppm/K
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
- 25 °C ... + 80 °C
- 40 °C ... + 85 °C
*) in this frequency range the limit line is of type SLOPING LINE
Generated:
Dunzow W.P.
Checked/Approved:
Dr. Bert Wall
VI TELEFILTER
Potsdamer Straße 18
Vectron International, Inc.
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Tel: (603) 598-0070 Fax: (603) 598-0075
Email: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as