English
Language : 

TFS70AC_06 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 70ac.doc
VI TELEFILTER
Version 1.3
Filter specification
TFS 70AC
03.03.2006
1/5
Measurement condition
Ambient temperature TA:
25 °C
Input power level:
0 dBm
Terminating impedances at fc *):
Input:
484 Ω || -22,0pF
Output:
127 Ω || -33,4pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 70AC is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency response of the filter in the operating temperature range.
Data
typ. value
tolerance / limit
Insertion loss
ae
(reference level)
Centre frequency at ambient temperature fc
Pass band
PB
Amplitude ripple within PB
7,5 dB
70
MHz
fc ± 3,6 MHz
0.3
dB
max. 9,5 dB
70,0 ± 0,1 MHz
fc ± 2,8 MHz
max. 1
dB
Relative attenuation
fc
fc ±
fc ±
.........
3,1 MHz .........
5,975 MHz .........
fc ± 3,1
fc ± 3,5
fc ± 20
arel
MHz
MHz
MHz
0,5 dB
2
dB
50
dB
max. 1
dB
max. 3
dB
min. 40
dB
Group delay at fc
Group delay ripple in PB
1,21 µs
68
ns
max. 120
ns
Phase linearity in fc ± 2,45 MHz
4
deg p-p
max.8
deg p-p
Operating temperature range
-
- 30 °C ... + 80
°C
Storage temperature range
-
- 40 °C ... + 85
°C
Temperature coefficient of frequency TCf**
- 94
ppm / K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fN (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.