English
Language : 

TFS675 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 675.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.3
Filter specification
23
°C
0
dBm
50
50
TFS 675
29.07.2004
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 675 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
ae
Nominal frequency
fN
Passband
Pass band ripple
Bandwidth
3 dB
Absolute attenuation
1
775
1350
MHz ...
MHz ...
MHz ...
Group delay ripple within PB
BW
575
1350
1500
MHz
MHz
MHz
aabs
Input power level
VSWR within PB
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
OTR
TCf *
typ. value
2
dB
-
0,7 dB
60
dB
48
dB
54
dB
7
ns
1,4:1
-
-
-72
ppm/K
tolerance / limit
max.
3 dB
675 MHz
fN ±
max.
15 MHz
1 dB
min.
40 MHz
min.
min.
min.
max.
30 dB
30 dB
50 dB
10 ns
max.
10 dBm
max. 1,6:1
- 40 °C ... + 85°C
- 40 °C ... + 85°C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.