Filename: tfs 622c.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.3
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 622C
17.08.2005
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 622C is the attenuation at nominal frequency. This value is defined as the insertion loss ae.
The nominal frequency fN is fixed at 622,08 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion Loss
ae
(reference level)
Nominal Frequency
fN
Centre Frequency
fC
Bandwidth
BW
3 dB
Relative Attenuation
arel
fN +
77,76 MHz … fN - 77,76 MHz
77,76 MHz … fN + 177,92 MHz
fN + 177,92 MHz …
1000,00 MHz
Input power level
Operating Temperature Range
Storage Temperature Range
Temperature Coefficient of Frequency
OTR
TCf *
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
typ. value
2,25 dB
-
622,08 MHz
11
MHz
67
dB
64
dB
55
dB
-
-
-36
ppm/K
tolerance / limit
4,0 dB
622,08 MHz
-
min.
60 dB
min.
60 dB
min.
48 dB
max.
10 dBm
- 25 °C ... + 85 °C
- 45 °C ... + 95 °C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.