English
Language : 

TFS500A Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 500a.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.1
Filter specification
23
°C
0
dBm
150 Ω
150 Ω
TFS 500A
1.12.2006
1/5
Characteristics
Remark:
The nominal frequency fN is fixed at 500,00 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 500A is the insertion loss ae. All specified data are met within the operating temperature range.
Data
Insertion Loss
ae
(reference level)
Nominal Frequency
fN
Bandwidth
BW
3 dB
Relative Attenuation
arel
62,5
430
562,5
MHz …
MHz …
MHz …
430 MHz
437,5 MHz
700 MHz
700 MHz …
1000 MHz
Input power level
Operating Temperature Range
Storage Temperature Range
Temperature Coefficient of Frequency
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
OTR
TCf *
typ. value
2,3 dB
-
12,0 MHz
56
dB
50
dB
55
dB
52
dB
-
-
-73
ppm/K
tolerance / limit
3,5 dB
500,00 MHz
-
min.
50 dB
min.
45 dB
min.
50 dB
min.
45 dB
max.
10 dBm
- 40 °C ... + 85 °C
- 45 °C ... + 95 °C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.