English
Language : 

TFS48B Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 48b.doc
Vectron International
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
231 Ω || -14.2 pF
426 Ω || -10.4 pF
TFS 48B
03.06.2010
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 48B is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 48 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band ripple
p-p
Relative attenuation
fN
fN
fN -
20
fN -
16
fN + 10
fN + 16
… fN ±
… fN ±
MHz … fN -
MHz … fN -
MHz … fN +
MHz … fN +
Group delay ripple in PB
2,5
3
16
10
16
20
Absolute group delay in PB
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
arel
MHz
MHz
MHz
MHz
MHz
MHz
at 23°C
OTR
TCf **
typ. value
12,5 dB
6,2 MHz
0,3 dB
0,5 dB
1,8 dB
67
dB
48
dB
43
dB
54
dB
55
ns
0,7 µs
-80
ppm/K
tolerance / limit
max.
15 dB
f±
N
max.
48 MHz
2,5 MHz
0,8 dB
max.
max.
min.
min.
min.
min.
1 dB
3 dB
55 dB
45 dB
40 dB
50 dB
max.
80 ns
max.
1 µs
- 40 °C ... + 85 °C
- 45 °C ... + 85 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.