English
Language : 

TFS468H Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 468h.doc
VI TELEFILTER
Version 1.1
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
120 Ω || -9 pF
70 Ω || -12 pF
TFS 468H
11.05.2007
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 468H is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 468,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
ae = amin
fN
Passband
PB
Pass band ripple
Relative attenuation
fN
… fN ±
9
fN ±
9
MHz … fN ± 10
fN ± 14,5 MHz … fN ± 17
fN ±
17
MHz … fN ± 25
f ± 72
N
MHz
f + 25
N
MHz … f + 532
N
fN - 467
MHz … fN -
25
Return loss
fN
… fN ± 10
Group delay ripple
fN
fN ±
… fN ±
9,5 MHz … fN ±
9,5
10
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
arel
MHz
MHz
MHz
MHz
MHz
MHz
arel
MHz
Gdr
MHz
MHz
OTR
TCf **
typ. value
10,6 dB
-
21,6 MHz
0,4 dB
0,4 dB
0,8 dB
19
dB
38
dB
58
dB
48
dB
50
dB
18
25
40
-
-
-18
ppm/K
tolerance / limit
max.
14,0 dB
fN
max.
468,0
± 9,0
1,0
MHz
MHz
dB
max.
max.
min.
min.
min.
min.
min.
1 dB
2,5 dB
15 dB
35 dB
50 dB
40 dB
40 dB
max.
8 dB
max.
max
250 ns
1,5 µs
- 40 °C ... + 85°C
- 45 °C ... + 85°C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.