English
Language : 

TFS466 Datasheet, PDF (1/3 Pages) Vectron International, Inc – Filter Specification
t_fs_4_6_6_.d_o_c_________________________________________________________________v_e_rs_i_on__1_.2_________________0_6_.0_1_._02
VI TELEFILTER
Filter Specification
TFS 466 - 1/3
_____________________________________________________________________________________________________
Measurement condition
Ambient temperature:
23
Input power level:
0
Input power level (impulse work): +16
Termination impedance:
Input :
50
Output:
50
°C
dBm
dBm
Ω
Ω
Construction and pin connection
see page 2
Remark:
Reference level for the relative attenuation arel of the TFS 466 is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 466,29 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
Characteristics
Data
typ. value
Variation/ Limitation
______________________________________________________________________________________________________
Insertion loss
ae = ami
-
max. 3,5 dB
(Reference level)
______________________________________________________________________________________________________
N__o_m__in_a_l_f_re_q__u_e_n_c_y_______________________fN___________________-_____________________________4_6_6_,2_9__M__H_z______
_C_e_n_te__r _fr_e_q_u_e_n_c_y_________________________f0________________4_6_6_,2_9__M__H_z_________________________-_____________
3 dB - bandwidth
BW
8,5 MHz
-
______________________________________________________________________________________________________
Ripple in pass band
_fN__±__2_____M__H_z____________________________________________-_________________________m_a_x_.____3____d_B________
Relative attenuation
arel
266.29 MHz ... 418 MHz
-
min. 65 dB
418
MHz ... 441.29 MHz
-
min. 40 dB
491.29 MHz ... 504 MHz
-
min. 40 dB
504
MHz ... 666.29 MHz
-
min. 65 dB
f_N_-___1_1_,5___M__H_z____________________________________________-_________________________m_i_n_.___6_0____d_B________
T__e_m_p_e_r_a_t_u_re__c_o_e_f_fi_c_ie_n_t_o__f _fr_e_q_u_e_n_c_y________T_C_f ______________-_3_2____p_p_m__/K________________________-_____________
Operating temperature range
- 20 °C ... + 75 °C
______________________________________________________________________________________________________
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.