English
Language : 

TFS456AG Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 456ag.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
800 Ω || -4,4 pF
900 Ω || -3,9 pF
TFS 456AG
15.02.2008
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 456AG is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 456,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Centre frequency
Passband
Pass band ripple
p-p
Bandwidth
1 dB
37 dB
Relative attenuation
f
N
f±
N
f±
N
4,6
20
…f ±
N
MHz … f ±
N
MHz … f ±
N
Group delay ripple within PB
2,5
20
50
Return loss within PB
Input power level
Operating temperature range
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
ae
fN
fC
PB
BW
arel
MHz
MHz
MHz
OTR
TCf **
typ. value
9,6 dB
-
456,0
-
0,3
MHz
dB
5,28 MHz
8,82 MHz
0,7 dB
43
dB
54
dB
39
ns
17
dB
-
-
-
25
-0,046
°C
ppm/K2
tolerance / limit
max.
14,0 dB
fN ±
max.
456,0
-
2,5
1
MHz
MHz
dB
min.
max.
5 MHz
9,2 MHz
max.
min.
min.
1 dB
37 dB
47 dB
max. 150 ns
min.
10 dB
max.
15 dBm
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
-
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.