English
Language : 

TFS455D Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 455d.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.1
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 455D
11.06.2004
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 455,0 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion Loss
ae
Nominal Frequency
fN
Passband
PB
Absolute attenuation
300 kHz …
350 MHz …
462,5 MHz …
467,5 MHz …
aabs
350
445
467,5
2000
MHz
MHz
MHz
MHz
Operating Temperature Range
Storage Temperature Range
Temperature Coefficient of Frequency
VSWR within PB(at ambient temperature)
Input Power Level
OTR
TCf *
typ. value
1,9 dB
-
-
39
35
40
36
-
-
- 36
1,7
-
dB
dB
dB
dB
ppm/K
tolerance / limit
2,8 dB
455,0 MHz
fN
± 2,5 MHz
min.
33 dB
min.
31 dB
min.
30 dB
min.
32 dB
- 10 °C ... + 85 °C
- 45 °C ... + 90 °C
-
max.
2:1
max.
20 dBm
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.