English
Language : 

TFS450A Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 450a.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.1
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 450A
01.02.2005
1/5
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 450A is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 450,00 MHz without tolerance. The given values for the relative
attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc
Data
Insertion loss
(reference level)
Nominal frequency
Centre frequency
Bandwidth 3dB
Relative attenuation
fN
-
42,8
MHz
ae= amin
fN
fC
BW
arel
typ. value
3,1 dB
-
--
450
MHz
9,2 MHz
75
dB
tolerance / limit
max.
4,5 dB
-
450,0 MHz
min.
4,0 MHz
min.
55 dB
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
OTR
TCf **
-
-
-34
ppm/K
- 10 °C ... + 55°C
- 30 °C ... + 80°C
-
** ∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.