1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
50
Ω
50
Ω
Characteristics
Remark:
The minimum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 430,0 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
ae
(reference level)
Nominal frequency
fN
Passband
PB
Pass band ripple
p-p
Bandwidth
1 dB
3 dB
Relative attenuation
fN
... fN ±
arel
12,5 kHz
Absolute attenuation
fN -
fN -
fN -
fN +
fN +
fN +
fN +
fN +
429,7
130
45
5
45
270
320
570
MHz ... fN - 130
MHz ... fN - 45
MHz ... fN -
5
MHz ... fN + 45
MHz ... fN + 270
MHz ... fN + 320
MHz ... fN + 570
MHz ... fN + 1470
aabs
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Group delay
Group delay
Group delay variation in PB
at fN
at fN at ambient temperature
p-p
Intermodulation *
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
OTR
TCf **
*) fin1= 429,98 MHz; fin2= 429,99 MHz; Pin= 0 dBm fmeasurement = 430,0 MHz
**) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
typ. value
1,6 dB
-
-
0,1 dB
3,2 MHz
4,4 MHz
0,1 dB
42,3
38,8
35,5
45,0
43,0
39,1
43,9
34,3
0,24
0,21
3
-
-
-
-
-33
dB
dB
dB
dB
dB
dB
dB
dB
µs
µs
ns
ppm/K
tolerance / limit
max.
4,0 dB
fN ±
max.
430,0
12,5
0,4
MHz
kHz
dB
-
-
max.
0,4 dB
min.
40 dB
min.
33 dB
min.
10 dB
min.
10 dB
min.
40 dB
min.
30 dB
min.
40 dB
min.
15 dB
max.
0,7 µs
max.
0,6 µs
max.
30 ns
min.
30 dBm
max.
17 dBm
-40 °C..... +85 °C
-55 °C..... +85 °C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.