English
Language : 

TFS426C Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 426c.doc
VI TELEFILTER
Version 1.1
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
230 Ω || -2,6 pF
230 Ω || -2,6 pF
TFS 426C
17.08.2006
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 426C is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 426,075 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
Nominal frequency
Centre frequency
ae = amin
fN
fC
1,8 dB
-
426,075 MHz
max.
3,0 dB
426,075 MHz
-
Passband
Pass band ripple
PB
p-p
-
0,07 dB
fN ± 6,25 kHz
max.
1,0 dB
Relative attenuation
fN -
f-
N
f-
N
fN +
fN +
fN +
6,25
419,20
4,20
2,30
3,80
8,80
kHz … fN +
MHz … f -
N
MHz … f -
N
MHz … fN +
MHz … fN +
MHz … fN +
Input power level
6,25
4,20
1,70
3,80
8,80
70,80
arel
kHz
MHz
MHz
MHz
MHz
MHz
0,07 dB
49
dB
40
dB
33
dB
37
dB
43
dB
-
max.
min.
min.
min.
min.
min.
max.
1,0
40
25
30
25
35
10
dB
dB
dB
dB
dB
dB
dBm
Operating temperature range
OTR
-
- 40 °C ... + 85°C
Storage temperature range
-
- 45 °C ... + 85°C
Frequency inversion temperature
36,0 °C
Temperature coefficient of frequency
TCf **
-0,036 ppm/K2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.