English
Language : 

TFS374G Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 374g.doc
VI TELEFILTER
Version 1.5
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
162 Ω || -8,2 pF
111 Ω || -9,8 pF
TFS 374G
17.04.2007
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 374G is the minimum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 374,5 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Passband ripple
fN -
fN -
2,0 MHz
12,5 MHz
relative attenuation
fN -
fN -
fN +
fN +
60,0
45,0
32,5
45,0
MHz … fN -
MHz … fN -
MHz … fN +
MHz … fN +
45,0
32,5
45,0
100
Group delay ripple
fN ±
2,0 MHz
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
arel
MHz
MHz
MHz
MHz
OTR
TCf *
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
typ. value
17,2 dB
-
29,7 MHz
0,3 dB
0,3 dB
48
dB
45
dB
47
dB
49
dB
10
ns
-
-
-
-19
ppm/K
tolerance / limit
max.
19,0 dB
374,5 MHz
fN ± 12,5 MHz
max..
max..
0,6 dB
1 dB
min.
42 dB
min.
42 dB
min.
30 dB
min.
35 dB
max.
15 ns
max.
10 dBm
- 10 °C ... + 70°C
- 45 °C ... + 85°C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.