English
Language : 

TFS368 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 368.doc
VI TELEFILTER
Version 1.1
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
200 Ω
200 Ω
TFS 368
27.11.2006
1/5
Characteristics
Remark:
The nominal frequency fN is fixed at 368,64 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 368 is the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3
dB filter attenuation level relative to the insertion loss ae. All specified data are met within the operating temperature range.
Data
Insertion loss
(reference level)
Nominal frequency
Centre frequency
Bandwidth
3 dB
Relative attenuation
0,3 MHz …
340
450
MHz …
490
490
MHz …
550
550
MHz …
800
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
ae
fN
fC
BW
arel
MHz
MHz
MHz
MHz
OTR
TCf *
typ. value
1,9 dB
-
368,64 MHz
8,7 MHz
55
dB
53
dB
47
dB
54
dB
-
-
-32
ppm/k
tolerance / limit
max.
3,5 dB
368,64 MHz
-
-
min.
50 dB
min.
47 dB
min.
42 dB
min.
48 dB
- 40 °C ... + 85°C
- 45 °C ... + 85°C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.