Filename: tfs 360l.doc
Vectron International
Version 1.4
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
84 Ω || -15,7 pF
64 Ω || -18,2 pF
TFS 360L
23.11.2009
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 360L is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 360 MHz without any tolerance or limit. The values of relative attenuation arel
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band ripple**
p-p
Relative attenuation
fN ...
fN ± 20
fN -
80 MHz ... fN -
70
fN -
70 MHz ... fN -
50
fN -
50 MHz ... fN -
40
fN +
fN +
fN +
40 MHz ... fN + 50
50 MHz ... fN + 80
80 MHz ... fN + 100
Group delay ripple within PB
Return loss
Input power level ***
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
arel
MHz
MHz
MHz
MHz
MHz
MHz
MHz
OTR
TCf ****
typ. value
8
dB
50
MHz
0,2 dB
0,2 dB
59
dB
46
dB
35
dB
25
dB
40
dB
44
dB
15
ns
12
dB
27
dBm
-85
ppm/K
tolerance / limit
max.
10,0 dB
fN
±
max.
360,0
20,0
0,5
MHz
MHz
dB
max.
min.
min.
min.
min.
min.
min.
1 dB
45 dB
35 dB
20 dB
10 dB
25 dB
35 dB
max.
50 ns
min.
10 dB
max.
20 dBm
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) over any 5MHz , fixed 3rd order detrend allowed if necessary
***) This power level is allowed for short term operation (<100 hours) only, the max. input power for continuous operation is 5 dBm.
****) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fN (MHz).
Generated:
Checked / Approved:
Filter characteristic
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.