VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
22
°C
0
dBm
118 Ω || -10.1 pF
150 Ω || - 9.9 pF
TFS 360K
05.09.2005
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 360K is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 360 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae
6.5
dB
max.
10,0 dB
Nominal frequency
Pass band
fN
PB
36,7 dB
360 MHz
fN
± 15
MHz
Amplitude ripple
p-p
0,3 dB
max.
1 dB
Amplitude ripple **
p-p
0,3 dB
Relative attenuation
fN -
15
MHz ... fN + 15
fN - 100
fN -
75
fN + 35
fN + 75
MHz ... fN - 75
MHz ... fN - 35
MHz ... fN + 75
MHz ... fN + 100
Group delay ripple in PB
arel
MHz
MHz
MHz
MHz
MHz
p-p
0,3 dB
55
dB
34
dB
35
dB
50
dB
14
ns
max.
min.
min.
min.
min.
max.
1 dB
40 dB
25 dB
25 dB
40 dB
50 ns
Group delay variation **
p-p
2
ns
max.
30 ns
VSWR **
1,5
min.
2
Input power level ***
max.
20 dBm
Operating temperature range
OTR
-40 °C ... + 85 °C
Storage temperature range
-45 °C ... + 85 °C
Temperature coefficient of frequency
TCf *****
-90
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) Applies over any 10MHz in PB
***) This power level is allowed for short term operation (10% of life time) only, the max. input power for continuous operation is 10 dBm.
****) ∆fc(Hz) = TCf(ppm/K) x (T - To) x fTo (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.