English
Language : 

TFS350K Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 350k.doc
Vectron International
Version 2.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
125 Ω || -5.5 pF
200 Ω || -7 pF
TFS 350K
18.03.2013
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS350K is the minimum of the pass band attenuation. This value is defined
as the insertion loss ae. The nominal frequency fN is fixed at 350,0 MHz without any tolerance. The values of relative attenuation arel
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is
included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae
13,4 dB
max.
14,5 dB
Nominal frequency
fN
350,0 MHz
Passband
Pass band ripple
PB
80,4 MHz
0,5 dB
fN ± 37,5 MHz
max.
1,0 dB
Bandwidth
1 dB
80,4 MHz
min.
75 MHz
40 dB
106
MHz
max. 125 MHz
Relative attenuation
fN -
37,5 MHz … fN +
fN - 100
MHz … fN -
fN -
62,5 MHz … fN -
fN + 51
MHz … fN +
fN + 62,5 MHz … fN +
fN + 100
MHz … fN +
Absolute group delay
37,5
62,5
51
62,5
100
2650
arel
MHz
MHz
MHz
MHz
MHz
MHz
0,6 dB
46
dB
30
dB
30
dB
42
dB
55
dB
0,27 µs
max.
min.
min.
min.
min.
min.
max.
1,0 dB
40 dB
25 dB
25 dB
40 dB
50 dB
0,5 µs
Group delay ripple within PB
16
ns
max. 100 ns
Return loss within PB
10
dB
min.
7 dB
IIP3
**
41
dBm
min.
40 dBm
Input power level
max.
10 dBm
Operating temperature range
OTR
- 30 °C ... + 60°C
Storage temperature range
- 45 °C ... + 85°C
Temperature coefficient of frequency
TCf ***
-91
ppm/K
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) fin1= 330MHz; fin2= 340MHz; Pin= 0dBm fmeasurement = 320MHz
***) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.