English
Language : 

TFS320 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 320.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance:
Input:
200
Ω
Output:
200
Ω
TFS 320
29.11.2005
1/5
Characteristics
Remark:
The nominal frequency fN is fixed at 320,0 MHz. The insertion loss ae is defined as loss value determined at fN. All specified data are met within the
operating temperature range.
Data
Insertion loss
(reference level)
Nominal frequency
Centre frequency
Bandwidth
3 dB
Absolute attenuation
fN -
fN +
fN -
fN +
fN +
fN -
80,00
80,00
160,00
160,00
240,00
240,00
MHz
MHz
MHz
MHz
MHz
MHz
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
ae
fN
fC
BW
aabs
OTR
TCf *
typ. value
1,4 dB
-
320,0
MHz
7,31 MHz
54
dB
52
dB
53
dB
51
dB
55
dB
59
dB
-
-
-32
ppm/K
tolerance / limit
max.
3,5 dB
320,0 MHz
-
min.
50 dB
min.
48 dB
min.
50 dB
min.
48 dB
min.
50 dB
min.
52 dB
max.
10 dBm
- 25 °C ... + 85 °C
- 45 °C ... + 95 °C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is