English
Language : 

TFS312 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 312.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance:
Input:
200
Ω
Output:
200
Ω
TFS 312
25.08.2006
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 312,5 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Pass band
Bandwidth
3 dB
Absolute attenuation
fN - 300
fN - 233
fN -
77
fN + 50
fN + 97
fN + 155
fN + 233
fN + 273
MHz … fN - 233
MHz … fN - 77
MHz … fN - 38
MHz … fN + 97
MHz … fN + 155
MHz … fN + 233
MHz … fN + 273
MHz … fN + 687,5
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
BW
aabs
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
OTR
TCf *
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
typ. value
2,2 dB
-
-
7,36 MHz
58
dB
54
dB
53
dB
52
dB
48
dB
52
dB
54
dB
54
dB
-
-
-32
ppm/K
tolerance / limit
max.
4,5 dB
fN ±
312,5
1,5
MHz
MHz
-
min.
52 dB
min.
50 dB
min.
48 dB
min.
48 dB
min.
44 dB
min.
48 dB
min.
50 dB
min.
52 dB
max.
10 dBm
- 40 °C ... + 85 °C
- 45 °C ... + 95 °C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.