Measurement condition
Ambient temperature: 23
Input power level:
0
Terminating impedances
for input:
for output:
External coil:
°C
dBm
540 Ohm // -1,7 pF
540 Ohm // -1,7 pF
116 nH
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 309 is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The nominal frequency fN is fixed on 309,6 MHz without tolerance. The specified values have to be reached in
operating temperature range.
Data
Insertion loss
ae
(Reference level)
Nominal frequency
fN
Centre frequency
fC
1 dB bandwidth
BW
Relative attenuation
arel
fN ± 1,8 MHz ... fN ± 6 MHz
fN ± 6 MHz ... fN ± 100 MHz
VSWR
@ fN
Group delay
GD
@ fN
Input power
Operating temperature range
Temperature coefficient of frequency TC
Frequency inversion temperature
typ.value
2,75 dB
-
309,62 MHz
270
kHz
47
dB
28...65
dB
1,2:1
2,6 µs
-
ca. – 0,036 ppm/K²
+ 25 °C
tolerance/limit
2,1 ... 4,1 dB
309,600 MHz
-
-
min. 30
dB
min. 20
dB
min. 1,8 : 1
max. 4,6 µs
max. 10
dBm
- 5 °C ... + 80 °C
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.