English
Language : 

TFS265 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 265.doc
VI TELEFILTER
Version 1.4
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
5
dBm
428 Ω || -6,2 pF
511 Ω || -6,2 pF
TFS 265
18.01.2006
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 265 is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 265,612 MHz without any tolerance or limit. The values of relative attenuation
arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the
production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae
3,4 dB
-
max.
4,0 dB
-
Nominal frequency
fN
-
265,612 MHz
Passband
Pass band ripple
-
0,5 dB
fN
+ 388
kHz
max.
1 dB
Relative attenuation
fN -
0,388 MHz ... fN +
fN -
fN +
fN +
fN +
fN +
55,612 MHz ... fN -
4,5 MHz ... fN +
5,388 MHz ... fN +
8,613 MHz ... fN +
9,388 MHz … fN +
arel
0,388 MHz
4,5 MHz
5,388 MHz
8,613 MHz
9,388 MHz
64,388 MHz
0,5 dB
50
dB
45
dB
48
dB
50
dB
50
dB
max.
min.
min.
min.
min.
min.
1 dB
40 dB
40 dB
45 dB
47 dB
40 dB
Group delay
mean value in PB
0,4 µs
max.
0,5 µs
Group delay ripple within PB
50
ns
max. 150 ns
Return loss within PB
16
dB
min.
10 dB
Input power level
-
max.
15 dBm
Operating temperature range
OTR
-
- 20 °C ... + 85 °C
Storage temperature range
-
- 40 °C ... + 90 °C
Temperature coefficient of frequency
TCf **
-17
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is