English
Language : 

TFS256 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 256.doc
VI TELEFILTER
Version 1.1
Filter specification
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance:
Input:
200
Ω
Output:
200
Ω
TFS 256
28.11.2005
1/5
Characteristics
Remark:
The nominal frequency fN is fixed at 256,0 MHz. The insertion loss ae is defined as loss value determined at fN. All specified data are met within the
operating temperature range.
Data
Insertion Loss
(reference level)
Nominal Frequency
Centre Frequency
Bandwidth
3 dB
Absolute Attenuation
fN -
fN +
fN ±
fN +
85,333 MHz
85,333 MHz
170,666 MHz
256,000 MHz
Input power level
Operating Temperature Range
Storage Temperature Range
Temperature Coefficient of Frequency
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
ae
fN
fC
BW
aabs
OTR
TCf *
typ. value
1,35 dB
-
256,0
MHz
5,85 MHz
53
dB
48
dB
51
dB
51
dB
-
-
- 32
ppm/K
tolerance / limit
max.
3,5 dB
256,0 MHz
-
min.
48 dB
min.
45 dB
min.
48 dB
min.
48 dB
max.
10 dBm
- 25 °C ... + 85 °C
- 45 °C ... + 95 °C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.