Vectron International
Measurement condition
Ambient temperature:
23
Input power level:
0
Terminating impedance:
Input:
50
Output:
50
Version 1.1
Filter specification
°C
dBm
Ω
Ω
TFS 2441A
22.09.2008
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 2441,75 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Pass band ripple
Absolute attenuation
0,3
1500
2700
MHz … 1500
MHz … 2200
MHz … 3500
VSWR within PB
MHz
MHz
MHz
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
ae
fN
PB
aabs
OTR
TCf *
typ. value
5,8 dB
-
-
1,0 dB
40
dB
33
dB
30
dB
1,8 : 1
-
-
-
-73
ppm/K
tolerance / limit
max.
6,5 dB
2441,75 MHz
fN
±
max.
41,75 MHz
2,0 dB
min.
min.
min.
max.
30 dB
25 dB
25 dB
3:1
max.
10 dBm
- 0 °C ... + 60 °C
- 40 °C ... + 80 °C
-
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.