English
Language : 

TFS230B Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 230b.doc
Vectron International
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
190 Ω || -12.8 pF
107 Ω || -18.9 pF
TFS 230B
14.12.2009
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 230B is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 230.4 MHz without any tolerance or limit. The values of relative attenuation
arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the
production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band ripple
p-p
Relative attenuation
fN ...
fN ± 20
fN -
fN +
fN +
10 MHz ... fN - 40
40 MHz ... fN - 32
40 MHz ... fN + 32
40 MHz ... fN + 220
Group delay ripple within PB
Return loss within PB
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
arel
MHz
MHz
MHz
MHz
MHz
OTR
TCf **
typ. value
9,1
44,2 MHz
0,6 dB
0,6
43
43
32
45
40
14
-92
ppm/K
tolerance / limit
max.
14,0 dB
fN
±
max.
230,4
20,0
1
MHz
MHz
dB
max.
min.
min.
min.
min.
1 dB
40 dB
35 dB
30 dB
40 dB
max.
75 ns
min.
10 dB
max.
15 dBm
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fN (MHz).
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such