English
Language : 

TFS2100 Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 2100.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.1
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 2100
26.02.2007
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 2100,0 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Absolute attenuation
1
2240
MHz ...
MHz …
1960
3000
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
aabs
MHz
MHz
OTR
TCf *
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).
typ. value
3,0 dB
-
62
MHz
38
dB
40
dB
-
-
-
- 50
ppm/K
tolerance / limit
max.
3,5
2100,0
dB
MHz
fN
± 23,0 MHz
min.
35 dB
min.
35 dB
max.
10 dBm
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.