English
Language : 

TFS2010 Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 2010.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.1
Filter specification
23
°C
0
dBm
50
50
TFS 2010
14.03.2007
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 2010,0 MHz without any tolerance or limit.
The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band variation
Absolute attenuation
50
1500
1930
2080
3000
5000
MHz
MHz
MHz
MHz
MHz
MHz
… 1500
… 1930
… 1940
… 3000
… 5000
… 6000
MHz
MHz
MHz
MHz
MHz
MHz
Return loss within PB
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
ae
fN
PB
aabs
OTR
TCf *
typ. value
1,7 dB
-
-
0,4 dB
41
dB
33
dB
33
dB
35
dB
22
dB
18
dB
19
dB
-
-
-
- 48
ppm/K
tolerance / limit
max.
2,5 dB
2010,0 MHz
fN
± 10,0 MHz
max.
1,0 dB
min.
20 dB
min.
30 dB
min.
25 dB
min.
30 dB
min.
17 dB
min.
10 dB
min.
10 dB
max.
10 dBm
- 40 °C ... + 85°C
- 40 °C ... + 85°C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.