English
Language : 

TFS1980A Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 1980a.doc
Vectron International
Version 2.0
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
257 Ω || -0,38 pF
61 Ω || -0,22 pF
TFS 1980A
08.12.2009
1/5
Characteristics
Remark:
The nominal frequency fN is fixed at 1980,0 MHz. The insertion loss ae is defined as loss value determined at fN. Reference level for the relative
attenuation arel of the TFS 1980 A is the insertion loss ae. All specified data are met within the operating temperature range.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band variation
Relative attenuation
0,3
862
1100
1771,3
2072,1
2119,8
3000
MHz
MHz
MHz
MHz
... 862
... 1100
... 1771,3
... 1887,4
MHz ... 2119,8
MHz ... 3000
MHz ... 6000
MHz
MHz
MHz
MHz
MHz
MHz
MHz
Group delay ripple
1961,6 MHz ... 1998,3 MHz
Input VSWR within PB
Output VSWR within PB
Permissible DC voltage
Operable temperature range
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
arel
OTR
TCf **
typ. value
2,9 dB
-
-
1,2 dB
66
dB
60
dB
49
dB
48
dB
40
dB
45
dB
44
dB
3
ns
1,8 : 1
1,8 : 1
-
-
-
- 43
ppm/K
tolerance / limit
max.
3,5 dB
1980,0 MHz
fN
±
max.
20,0 MHz
2,0 dB
min.
55 dB
min.
46 dB
min.
40 dB
min.
33 dB
min.
33 dB
min.
35 dB
min.
15 dB
max.
10 ns
max.
2,2 : 1
max.
2,2 : 1
max.
0V
- 30 °C ... + 80 °C
- 20 °C ... + 50 °C
- 50 °C ... +125 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.