English
Language : 

TFS196_02 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter Specification
TFS196.doc
VI TELEFILTER
Filter Specification
version 1.2
TFS 196
17.01.02
1/5
Measurement condition
Ambient temperature: 23
Input power level:
0
Terminating impedances *:
°C
dBm
for input:
for output:
253 Ω // -12,9 pF
265 Ω // -13,2 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 196 is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid both for the reference frequency fc and the frequency
response of the filter at the operating temperature. The frequency shift of the filter at the operating temperature not included in the production
tolerance scheme.
Data
Insertion Loss
(Reference Level)
Nominal Frequency
Centre Frequency
fC
(at ambient temperature)
Pass band
PB
Group delay ripple in PB
typ. Value
8,0 dB
196,99 MHz
-
0,1 µs
Limit
max. 9,0 dB
196,990 MHz
196,99 ± 0,03 MHz
fc ± 0,280 MHz
max
0,30 µs
Relative Attenuation
arel
fc
... fc ± 0,280 MHz
fc ± 0,296 MHz ... fc ± 0,75 MHz
@
fc ± 0,75 MHz
@
fc ± 1,55 MHz
fc ± 3,1 MHz ... fc ± 8,0 MHz
fc - 21
MHz ... fc - 19
MHz
fc - 11
MHz ... fc - 9
MHz
-
-
25 dB
60 dB
60 dB
70 dB
65 dB
max.
min.
min.
min.
min
min
min
3,0 dB
3,0 dB
20
dB
55
dB
55
dB
60
dB
60
dB
Operating Temperature Range
-10 ... 50
°C
Storage Temperature Range
-40 ... 85
°C
Temperature Coefficient TC
- 0,036 ppm / K2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
generated:
checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.