English
Language : 

TFS1960 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Preliminary Specification
TFS1960.doc
VI TELEFILTER
version 1.2
Preliminary Specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
for input:
for output:
23 C
0 dBm
50
50
TFS 1960
08.01.2004
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1960 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss
Nominal frequency
Pass band
Pass band ripple
Absolute attenuation
ae
fN
PB
aabs
10 MHz ... 1850
1850 MHz ... 1910
2010 MHz ... 2040
2040 MHz ... 2070
2070 MHz ... 5000
5000 MHz ... 6000
MHz
MHz
MHz
MHz
MHz
MHz
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
Input power level
*) f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
TCf*)
typ. value
2,70 dB
-
80,65 dB
0,6 dB
33
dB
18
dB
7,3 dB
45
dB
35
dB
14
dB
-
-
-36 ppm/K
-
tolerance/limit
max. 4,1 dB
1960
MHz
fN 30
max. 2
MHz
dB
min. 24
dB
min. 11,5 dB
min. 5,5 dB
min. 30
dB
min. 23
dB
min. 10
dB
- 10 °C ... + 70 °C
- 40 °C ... + 85 °C
-
max. 5
dBm
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com