English
Language : 

TFS190N Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter Specification
TFS 190N.doc
VI TELEFILTER
Measurement condition
version 1.4
Filter Specification
TFS 190N
20.08.2004
1/5
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
Characteristics
23
°C
0
dBm
116 Ω || -16,2 pF
116 Ω || -16,2 pF
Remark:
The reference level for the relative attenuation arel of TFS190N is the minimum of the pass band attenuation amin. This value is defined as the insertion
loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 1 dB filter attenuation level relative to the insertion
loss ae. The given values for the relative attenuation arel and the group delay ripple have to be reached at the frequencies given below, even if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the
centre frequency fc.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae
7,8 dB
-
max.
9,5 dB
Nominal frequency
Centre frequency
fN
-
fC
190
MHz
190 MHz
-
Passband
PB
-
fN
± 7,12 MHz
Ripple in PB (p-p)
(over any 3,84 MHz span)
0,4 dB
-
max.
0,8 dB
Phase ripple in PB (p-p)
(over any 3,84 MHz span)
Relative attenuation
fN
... fN ±
fN ±
fN +
14,14 MHz ... fN ±
100
MHz ... fN +
7,3
100
810
arel
MHz
MHz
MHz
2,9 deg
-
0,7 dB
36
dB
50
dB
max.
4 deg
max.
min.
min.
1 dB
34 dB
40 dB
Absolute group delay variation in PB **
7
ns
max.
9 ns
Group delay ripple within PB
35
ns
max.
50 ns
Input power level ***
-
max.
21 dBm
Operating temperature range
OTR
-
- 10 °C .... + 85°C
Storage temperature range
-
- 40 °C .... + 85°C
Temperature coefficient of frequency
TCf ****
-87
ppm/K
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) Maximum variation of the mean value messured from 182,88 MHz to 197,12 MHz within operating temperature range.
***) Maximum value for 10 years operation.
****) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz).
Generated:
Checked / Approved:
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed as a
result of their use or application. No rights under any patent accompany the sale of any such product(s) or information