Filter Specification
Measurement condition
Ambient temperature TA:
Input power level:
Terminating impedances at fc: *
25 °C ± 2°C
0 dBm
input:
1076
output:
831
- 5,8 pF
- 6,6 pF
TFS 188 A
14.08.2003
1/5
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 188A is the minimum of the pass band attenuation amin. The minimum of
the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower
frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 188 MHz without tolerance. The
given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre
frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance
for the centre frequency fc.
Data
typ. value
tolerance / limit
Insertion loss
ae
(reference level)
4,8 dB
max. 6
dB
Nominal frequency
fN
Centre frequency
fC
-
188 MHz
188
MHz
-
Relative attenuation
arel
fN
.......
fN ± 0,06
fN ± 0,06 MHz ....... fN ± 0,12
fN ± 0,8
fN ± 1,6
fN ± 3,2
MHz ....... fN ± 1,6
MHz ....... fN ± 3,2
MHz ....... fN ± 10
MHz
MHz
MHz
MHz
MHz
0,15 dB
0,8 dB
38 dB
43 dB
47 dB
max. 0,29 dB
max. 3
dB
min. 35
dB
min. 36
dB
min. 40
dB
Absolute group delay at fN
Group delay variation in fN ± 0,12 MHz
1,5 µs
120 ns
max. 5
µs
max. 250
ns
Temperature coefficient of frequency Tcf **
- 0,04 ppm/K²
-
Operating temperature range
-
- 25 °C ... + 75 °C
Storage temperature range
-
- 40 °C ... + 85 °C
Frequency inversion temperature T0
35 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz)
generated:
checked / approved:
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.