English
Language : 

TFS180C Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 180c.doc
VI TELEFILTER
Version 1.1
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0
dBm
95 Ω || -3,1 pF
220 Ω || -3,1 pF
TFS 180C
12.09.2007
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 180C is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 180,0 MHz without any tolerance. The given values for both the
relative attenuation arel and the group delay ripple have to be achieved at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
Insertion loss
(reference level)
Nominal frequency
Centre frequency at ambient temperature
Passband
Pass band ripple
p-p
Amplitude ripple at fC ± 15 MHz p-p
Bandwidth
1 dB
3 dB
40 dB
Relative attenuation
fC
fC ±
22
fC ±
50
… fC ±
MHz … fC ±
MHz … fC ±
18,0
50
100
Group delay ripple within PB p-p
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
fC
PB
BW
arel
MHz
MHz
MHz
OTR
TCf **
typ. value
17,2 dB
-
180,0
-
0,25
0,25
MHz
dB
dB
37,11
38,51
43,76
MHz
MHz
MHz
0,6
43
56
42
-
-
-80
dB
dB
dB
ns
ppm/K
tolerance / limit
max.
20,0 dB
180,0 MHz
± 0,1 MHz
fC
± 18,0
max.
1
MHz
dB
max.
0,5 dB
min.
min.
max.
36 MHz
38 MHz
44 MHz
max.
min.
min.
1 dB
40 dB
50 dB
max. 100 ns
- 40 °C ... + 85 °C
- 40 °C ... + 85 °C
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz).
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is