English
Language : 

TFS1732A Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 1732a.doc
Vectron International
Version 2.1
Filter specification
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance:
Input:
50
Ω
Output:
50
Ω
TFS 1732A
12.03.2012
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS1732A is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1732.5MHz without any tolerance or limit. The values of relative attenuation arel
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
Nominal frequency
Passband
Pass band variation
Relative attenuation
1650 MHz ... 1670 MHz
1670 MHz … 1690 MHz
1775 MHz … 1795 MHz
1795 MHz ... 1815 MHz
Return loss within PB
ae
fN
PB
arel
2 dB
1 dB
30 dB
15 dB
16 dB
32 dB
11
max.
3.0 dB
1732.5 MHz
fN
± 22.5 MHz
max.
2 dB
min.
min.
min.
min.
min.
25 dB
5 dB
5 dB
25 dB
9 dB
Input power level
-
max.
10 dBm
Operating temperature range
OTR
-
- 40 °C ... + 85 °C
Storage temperature range
-
- 40 °C ... + 85 °C
Temperature coefficient of frequency
TCf *
-40 ppm/K
-
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz)
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.