English
Language : 

TFS167F Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 167f.doc
VI TELEFILTER
Version 2.0
Filter specification
TFS 167F
29.10.2004
1/5
Measurement condition
Ambient temperature:
23 C
Input power level:
0 dBm
Terminating impedances at fc *: input:
output:
869
1058
-8,5 pF
-5,9 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 167F is the minimum of the pass band attenuation amin. The maximum of the pass band
attenuation is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 2 dB filter
attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed at 167 MHz without tolerance. The given values for the relative
attenuation arel and for the group delay ripple have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
Data
typ. Value
Limit
Insertion loss
ae
5,8 dB
max. 7 dB
Nominal frequency
fN
-
167 MHz
Passband
PB
-
fN ± 75 kHz
Amplitude variation in PB
p-p
Amplitude ripple in PB
p-p
0,7 dB
0,05 dB
max.
max.
1,5 dB
1 dB
Relative Attenuation
fN ± 0,2 MHz ... fN ± 0,4
fN ± 0,4 MHz ... fN ± 0,6
fN ± 0,6 MHz ... fN ± 0,8
fN ± 0,8 MHz ... fN ± 1,6
fN ± 1,6 MHz ... fN ± 20
fN - 137 MHz ... fN - 20
fN + 20 MHz ... fN + 103
fN +103 MHz ... fN + 105
fN +105 MHz ... fN + 1
arel
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
GHz
Group delay variation in PB
Group delay in PB
3,5 dB
25 dB
43 dB
45 dB
47 dB
73 dB
73 dB
67 dB
75 dB
200 ns
2,4 µs
min. 2 dB
min. 17 dB
min. 36 dB
min. 41 dB
min. 41 dB
min. 67 dB
min. 67 dB
min. 60 dB
min. 67 dB
max. 400 ns
max. 2,6 µs
Input return loss in PB
Output return loss in PB
20 dB
18 dB
min. 15 dB
min. 10 dB
Input Power Level
Temperature coefficient of frequency Tcf
Frequency inversion temperature T0
Operating temperature range
Storage temperature range
-
- 0,036 ppm/K2
35 °C
-
-
max. 22 dBm**)
-
-
- 5 °C .. + 85 °C
- 40 °C.. + 90 °C
Intermodulation ratio
120 dB
min. 100 dB
input signals at 167 + 0,8 MHz and 167 + 1,6 MHz or at 167 - 0,8 MHz and 167 - 1,6 MHz, each at -20 dBm
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) This power level is only allowed for short term operation (1% of the life time), the max. input power for continuous operation is max.15dBm only
generated:
checked / approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.