English
Language : 

TFS1590C Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 1590c.doc
Vectron International
Measurement condition
Ambient temperature:
23
Input power level:
0
Terminating impedance:
Input:
200
Output:
200
Version 1.0
Filter specification
°C
dBm
Ω
Ω
TFS 1590C
21.08.2013
1/5
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1587.5 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss in PB
Nominal frequency
Passband
Pass band ripple
Pass band variation
Absolute attenuation
0.3 MHz … 1515
1658 MHz … 1685
1685 MHz … 2000
Group delay ripple
MHz
MHz
MHz
1565 MHz … 1585
1593 MHz … 1610
Group delay variation
(unit to unit)
VSWR within PB
MHz
MHz
Input power level in PB
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
p-p
aabs
**)
OTR
TCf *
*) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz)
**) measured at 1569 MHz, 1587.5 MHz, 1610 MHz
typ. value
4.0 dB
-
-
0.7 dB
1.7 dB
32
dB
50
dB
36
dB
7
ns
9
ns
+/- 3
ns
1.9 : 1
-
-
-
-76
ppm/K
tolerance / limit
max.
4.5 dB
1587.5 MHz
fN ± 22.5 MHz
max.
1.0 dB
max.
2.5 dB
min.
30 dB
min.
20 dB
min.
30 dB
max.
10 ns
max.
15 ns
max. +/- 5 ns
max.
2.2 : 1
max.
10 dBm
- 40 °C ... + 85°C
- 45 °C ... + 85°C
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or
information.