English
Language : 

TFS1584 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 1584.doc
Vectron International
Version 2.3
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
50 Ω
50 Ω
TFS 1584
19.04.2013
1/5
Characteristics
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1584.0 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
Insertion loss in PB
Nominal frequency
Passband
Passband variation within PB
Passband ripple within PB
Absolute attenuation
100
MHz … 1500
1500 MHz … 1539
1629 MHz … 2500
2500 MHz … 3000
Return loss within PB
MHz
MHz
MHz
MHz
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
ae
fN
PB
aabs
OTR
TCf *
typ. value
2.7
-
-
0.8
0.35
47
46
47
40
12.5
-
-
-
-38
MHz
MHz
MHz
MHz
dB
ppm/K
tolerance / limit
max.
4.0
1584.0
fN ± 10.0
max.
2.5
max.
1.0
dB
MHz
MHz
dB
dB
min.
40 dB
min.
30 dB
min.
40 dB
min.
35 dB
min.
10 dB
max.
20 ** dBm
- 45 °C ... + 105°C
- 45 °C ... + 105°C
*) ∆fc(Hz) = Tcf(ppm/K) x (T - To) x fCAT (MHz)
**) This power level is allowed for short term operation (peak power) only, the max. input power for continuous operation is 10 dBm.
Generated:
Checked / Approved:
Vectron International GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.