TFS156B Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 156b.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.5
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 156B
21.02.2006
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 156B is the maximum of the pass band attenuation. This value is defined as the insertion
loss ae. The nominal frequency fN is fixed at 156,65 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole
operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Pass band ripple
Bandwidth
0,5 dB
0,5 dB
3 dB
Relative attenuation
f±
N
f±
N
fN ±
fN ±
3,00
5,00
8,00
9,00
MHz … f ±
N
MHz … f ±
N
MHz … fN ±
MHz … fN ±
Input power level
ae = amax
fN
PB1
PB2
BW
5,00
8,00
9,00
20,00
arel
MHz
MHz
MHz
MHz
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆f(Hz) = TCf(ppm/K) x (T-T0) x fcat(MHz).
OTR
TCf *
typ. value
1,25 dB
-
-
-
-
3,7 MHz
18
dB
25
dB
40
dB
50
dB
-
-
-
- 32
ppm/K
tolerance / limit
max.
2,5 dB
156,525
156,800
max.
156,65 MHz
± 0,025 MHz
± 0,025 MHz
± 0,5 dB
min. 156,525
min. 156,800
± 0,025 MHz
± 0,025 MHz
-
min.
10 dB
min.
20 dB
min.
25 dB
min.
40 dB
max.
15 dBm
- 40 °C ... + 85°C
- 45 °C ... + 90°C
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.