English
Language : 

TFS156 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter Specification
Tfs156.doc
VI TELEFILTER
version 1.5
Filter Specification
TFS 156
13.07.2000
1/5
Measurement condition
Ambient temperature: 23
Input power level:
0
Terminating impedances
for input:
for output:
°C
dBm
630 Ohm // -1,5 pF
630 Ohm // -1,5 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 156 is the insertion loss. The insertion loss ae is defined as the insertion loss at the
nominal frequency fN . The centre frequency fC is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level
relative to the insertion loss ae. The nominal frequency fN is fixed on 156 MHz without tolerance. The specified values have to be reached in
operating temperature range.
Data
Insertion loss
ae
(Reference level)
Nominal frequency
fN
Centre frequency
fC
1 dB bandwidth
BW
Relative attenuation
arel
fN ± 1,8 MHz ... fN ± 6 MHz
fN ± 6 MHz ... fN ± 100 MHz
VSWR
@ fN
Group delay
GD
@ fN
Input power
Over 0.01% of life time
Operating temperature range
Temperature coefficient of frequency TC
Frequency inversion temperature
typ. value
-
-
156,007 MHz
78
kHz
57...70
dB
57...70
dB
1,2 : 1
9,1 µs
-
-
ca. – 0,036 ppm/K²
+ 35 °C
tolerance/limit
1,7 ... 3,7 dB
156,000 MHz
-
-
min. 30
dB
min. 20
dB
min. 1,8 : 1
max. 13
µs
max. 4
max. 10
dBm
dBm
- 5 °C ... + 80 °C
Generated:
Checked / approved:
VI TELEFILTER
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.