English
Language : 

TFS155 Datasheet, PDF (1/2 Pages) Vectron International, Inc – Filter Specification
t_fs_1_5_5_.d_o_c______________________________________________________________V_e_r_si_o_n_1_.2______________1_5_.0_2_._02_______
VI TELEFILTER
Filter Specification
TFS 155 - Page 1 /2
______________________________________________________________________________________________________
Measurement condition
Ambient temperature: 23 °C
Input power level:
0 dBm
Terminating impedances:
Input:
:
Output
:
670 Ω // -1 pF
670 Ω // -1 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 155 is the maximmum pass band attenuation, which is is defined as
the insertion loss ae. The nominal frequency fN is fixed at 155,52 MHz without tolerance or limit. The values of relative
attenuation arel are guaranteed in the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
______________________________________________________________________________________________________
Insertion loss
ae
2,5
max. 5
dB
(Reference level)
______________________________________________________________________________________________________
N__o_m__in_a_l_f_re_q__u_e_n_c_y_______fN__________________________________1_5_5_,5_2_5__M_H_z_____________________1_5_5_,5_2____M_H_z_____
Usable signal band width
min. ± 10
kHz
______________________________________________________________________________________________________
Relative attenuation
arel
fN + 910 kHz
70 dB
min. 65
dB
_fN____±____3___M_H_z____f_N__±___1_0___M_H_z____________________________6_5_d_B_____________________m_i_n_.___5_0______d_B______
_T_e_m_p_e_r_a_t_u_re__c_o_e_f_fi_c_ie_n_t_o__f _fr_e_q_u_e_n_c_y________T_C_f__*)______________-__0_,0_3_6__p_p_m__/K__² ___________________-_____________
F__re_q_u__e_n_c_y_i_n_v_e_rs_i_o_n__te_m__p_e_r_a_tu_r_e___________T_o________________+__2_5_____°_C________________________-_____________
Operating temperature range
- 10 °C ... + 50 °C
______________________________________________________________________________________________________
*) ∆f(Hz) = TCf(ppm/K²) x (∆T)² x fTo(MHz)
generated:
checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron International, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.