Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
25
°C
02
dBm
330 Ω || -13,6 pF
300 Ω || -14,6 pF
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 150S is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fc is the arithmetic mean value of the upper and lower frequencies at the 3 dB
filter attenuation level relative to the insertion loss ae. The temperature coefficient of frequency Tcf is valid for both the reference frequency fc and the
frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating temperature range is not included in the
production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss
(reference level)
ae
21,6 dB
max.
25 dB
Nominal frequency
fN
-
150,0 MHz
Centre frequency
fC
150
MHz
150,0±0,1 MHz
Passband
PB
-
Pass band ripple (p-p)
0,25
fC
max.
±2,5015 MHz
0,7 dB
Bandwidth
0,7 dB
3 dB
40 dB
45 dB
Relative attenuation
fC
fC ±
fC -
fC ±
fC ±
fC ±
fC +
… fC ±
2,5015 MHz … fC ±
144,500 MHz … fC -
3,150 MHz … fC ±
3,350 MHz … fC ±
3,750 MHz … fC ±
4,825 MHz … fC +
Absolute group delay within PB
BW
arel
2,5015 MHz
2,675 MHz
4,825 MHz
3,350 MHz
3,750 MHz
4,825 MHz
428,500 MHz
5,20 MHz
5,53 MHz
6,49 MHz
6,54 MHz
0,25 dB
1,5 dB
65
dB
20
dB
45
dB
55
dB
60
dB
2,58 µs
min.
min.
max.
max.
max.
max.
min.
min.
min.
min.
min.
max.
5,03 MHz
5,35 MHz
7,50 MHz
9,70 MHz
0,7 dB
3,0 dB
45 dB
15 dB
25 dB
40 dB
45 dB
2,7 µs
Group delay ripple within PB (p-p)
44
ns
max. 120 ns
Operating temperature range
OTR
-
- 25 °C ... + 80°C
Storage temperature range
-
- 40 °C ... + 85°C
Frequency inversion temperature
20
°C
-
Temperature coefficient of frequency
TCf **
-0,036 ppm/K2
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference
values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) ∆fc(Hz) = Tcf(ppm/K2) x (T - TA)2 x fCAT (MHz)
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.