English
Language : 

TFS150 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 150.doc
VI TELEFILTER
Version 1.2
Filter specification
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
23
°C
0
dBm
930 Ω || -1,6 pF
930 Ω || -1,6 pF
TFS 150
11.11.2005
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 150 is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at MHz without any tolerance or limit. The values of relative attenuation arel are
guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
Insertion loss
(reference level)
Nominal frequency
Passband
Bandwidth
3 dB
Relative attenuation
fN + 910
kHz
Operating temperature range
Storage temperature range
Frequency inversion temperature
Temperature coefficient of frequency
*) ∆f(Hz) = TCf(ppm/K2) x (T-T0)2 x fTo(MHz)
ae= amax
fN
PB
BW
arel
OTR
TCf *
typ. value
2,8 dB
-
-
107
kHz
65
dB
-
-
+ 30 °C
- 0,036
ppm/K2
tolerance / limit
max.
5 dB
150,05 kHz
fN ± 10 kHz
-
min.
60 dB
- 20 °C ... + 70 °C
- 30 °C ... + 75 °C
-
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.