TFS140V_06 Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
Filename: tfs 140v.doc
VI TELEFILTER
Version 1.2
Filter specification
TFS 140V
30.08.2006
1/5
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance: *
Input:
Output:
23
°C
0.
dBm
50
Ω
50
Ω
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 140V is the minimum of the pass band attenuation. This value is defined as the insertion loss
ae. The nominal frequency fN is fixed at 140,0 MHz without any tolerance. The values of relative attenuation arel are guaranteed for the whole operating
temperature range. The frequency shift of the filter in the operating temperature range is included in the production tolerance scheme.
Data
typ. value
tolerance / limit
Insertion loss (reference level) ae = amin
Nominal frequency
23
dB
-
max. 24,25 dB
140,0 MHz
Pass band
PB
Pass band ripple ( p–p )
Relative attenuation
arel
fN
... fN ± 2,45 MHz
fN ± 2,45 MHz ... fN ± 2,625 MHz
fN
... fN ± 2,4 MHz **
fN ± 2,4 MHz ... fN ± 2,6 MHz **
fN + 3,85 MHz
fN + 5 MHz
fN - 5 MHz
fN - 125 MHz
... fN + 5
... fN + 210
... fN - 3,9
... fN - 5
MHz
MHz
MHz
MHz
Group delay ( mean value in PB )
Group delay ripple in PB
-
0,6 dB
0,8 dB
2,2 dB
0,8 dB
2,2 dB
52
dB
54
dB
55
dB
52
dB
1,8 µs
65
ns
fN ±
max.
2,4 MHz
1 dB
max.
max.
max.
max.
min.
min.
min.
min.
1 dB
3 dB
1 dB
3 dB
40 dB
50 dB
40 dB
50 dB
max.
2,1 µs
max. 100 ns
Phase linearity in PB
3,5 deg
max.
5 deg
Temperature coefficient of frequency Tcf
Frequency deviation of fc over temperature
Operating temperature range
** extended operating temperature range
Storage temperature range
- 18
ppm/K
-
∆fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
-
+ 10 °C...+ 70 °C
-
- 35 °C...+ 80 °C
-
- 40 °C... + 85 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as reference values
only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.