English
Language : 

TFS125H Datasheet, PDF (1/5 Pages) Vectron International, Inc – Filter specification
tfs125H.doc
VI TELEFILTER
Filter specification
version 1.2
TFS 125 H
18.06.2003
1/5
Measurement Condition
Ambient temperature:
23 C
Input power level:
0 dBm
Source impedance:
50 single ended
Load impedance:
50 single ended
Terminating impedances: *) input: 1,03 k // -15,4 pF
output: 0,88 k // -14,8 pF
Characteristics
Remark: Reference level for the relative attenuation arel of the TFS 125H is the minimum of the pass band attenuation. Reference for the echo
response attenuation is the main time response lobe, the reference time is defined as t0. The nominal frequency fN is fixed at 125 MHz without
tolerance. The given values for the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below even
if the centre frequency fc is shifted due to the temperature coefficient of frequency TCf in the operating temperature range and due to a
production tolerance for the centre frequency fc.
Data
typ. Value
Limit
Absolute attenuation within PB
8 dB
7... 10 dB
Nominal frequency fN
-
125 MHz
Pass band (PB)
1 dB bandwidth
-
1,6 MHz
fN
0,6 MHz
min. 1,2 MHz
Relative attenuation
fN
... fN
fN
0,1 MHz ... fN
fN
0,4 MHz ... fN
arel
0,1 MHz
0,4 MHz
0,6 MHz
fN 1,2 MHz ... fN 1,8 MHz
fN 1,8 MHz ... fN 6 MHz
fN 6 MHz ... fN 13 MHz
fN - 13 MHz ... fN - 115 MHz
fN + 13 MHz ... fN + 325 MHz
Echo response attenuation arel
t0 + 2 µs
t0 + 3 µs
t0 + 4 µs
t0 + 5 µs
t0 + 6 µs
Group delay
at fN
Group delay ripple within PB
-
-
-
7 dB
22 dB
45 dB
65 dB
70 dB
37 dB
46 dB
56 dB
65 dB
78 dB
700 ns
50 ns
max.
max.
max.
min.
min.
min.
min.
min.
0,4 dB
0,7 dB
1,85 dB
6 dB
15 dB
40 dB
50 dB
50 dB
min. 30 dB
min. 40 dB
min. 50 dB
min. 55 dB
min. 60 dB
max. 800 ns
max. 150 ns
Input power level
-
max. + 10 dBm
VSWR
within PB
14 dB
min. 2 : 1
Intermodulation products **
70 dBm
min. 60 dBm
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
Frequency inversion temperature
TCf ***
T0
-
-
-0,04
20
ppm/K2
°C
- 10 °C ... + 85 °C
- 40 °C ... + 125 °C
-
-
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions, do not hesitate to ask for an application note or contact our design team.
**) fin,1=125MHz; fin,2=125,1MHz; Pin=4dBm+loss at fN; fout,1=124,9MHz; fout,2=125,2MHz; then Pout <-56dBm
***) f(Hz) = TCf(ppm/K²) x (T-T0)² x fTo(MHz)
generated:
checked / approved:
TELEFILTER GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
e-mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.