English
Language : 

TFS1240A Datasheet, PDF (1/5 Pages) Vectron International, Inc – Vectron International Filter specification
Filename: tfs 1240a.doc
Vectron International
Measurement condition
Ambient temperature:
23
Input power level:
0
Terminating impedance:
Input:
50
Output:
50
Version 2.0
Filter specification
°C
dBm
Ω
Ω
TFS 1240A
31.03.2009
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 1240A is the maximum attenuation in the pass band. The maximum attenuation in the pass
band is defined as the insertion loss ae. The nominal frequency fN is fixed at 1240 MHz without any tolerance or limit. The values of relative attenuation arel
are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the production
tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband
Pass band variation
p-p
Passband 2
Pass band variation in PB2
p-p
Relative attenuation
1069
1167
MHz … 1131
MHz … 1173
MHz
MHz
Group delay ripple within PB
p-p
Return loss
Input power level
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆ f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz)
ae
fN
PB
PB2
arel
OTR
TCf *
typ. value
4,2 dB
-
-
1,4 dB
-
0,4 dB
40
dB
18
dB
12
ns
16
dB
-
-
-
-73
ppm/K
tolerance / limit
max.
6,0 dB
1240,0
fN
±
max.
28,0
3,0
fN
±
max.
12,0
0,6
MHz
MHz
dB
MHz
dB
min.
37 dB
min.
12 dB
max.
25 ns
min.
10 dB
max.
0 dBm
- 10 °C ... + 75 °C
- 20 °C ... + 80 °C
-
Generated:
Checked / Approved:
Vectron International GmbH & Co. KG
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
Vectron International GmbH & Co. KG reserves the right to make changes to the product(s) and/or information contained herein without
notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.