English
Language : 

TFS1240 Datasheet, PDF (1/5 Pages) Vectron International, Inc – VI TELEFILTER Filter specification
Filename: tfs 1240.doc
VI TELEFILTER
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
Input:
Output:
Version 1.4
Filter specification
23
°C
0
dBm
50
Ω
50
Ω
TFS 1240
25.02.2008
1/5
Characteristics
Remark:
The reference level for the relative attenuation arel of the TFS 1240 is the maximum attenuation in the passband 1. The maximum attenuation in the pass
band 1 is defined as the insertion loss ae. The nominal frequency fN is fixed at 1240 MHz without any tolerance or limit. The values of relative attenuation
arel are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating temperature range is included in the
production tolerance scheme.
Data
Insertion loss
Nominal frequency
Passband 1
Passband 2
Pass band variation 1
Pass band variation 2
Relative attenuation
1077,5
1122,5
1170,0
MHz
MHz
MHz
Group delay ripple within PB
p-p
Return loss
Operating temperature range
Storage temperature range
Temperature coefficient of frequency
*) ∆ f(Hz) =TCf(ppm/K) x(T-T0) x fTo (MHz)
ae
fN
PB
PB
arel
OTR
TCf *
typ. value
3,5 dB
-
-
-
0,6 dB
1,0 dB
54
dB
50
dB
44
dB
6
ns
11
dB
-
-
-72
ppm/K
tolerance / limit
max.
5,0 dB
1240,0
fN ± 14,5
fN ± 22,5
max.
1,0
max.
2,0
MHz
MHz
MHz
dB
dB
min.
50 dB
min.
47 dB
min.
30 dB
max.
25 ns
min.
10 dB
- 10 °C ... + 75 °C
- 40 °C ... + 85 °C
-
Generated:
Checked / Approved:
Tele Filter GmbH
Potsdamer Straße 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@vectron.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.